* Fourfit control file for experiment 2491 max_parity 0.01 if f_group X or f_group S sb_win -0.3 0.3 mb_win -1.0 1.0 dr_win -.000008 .000008 if station D or station L switched scan_start period 30 * gates abcegh 0 30 20 10 5 10 5 10 20 10 0 30 gates abcegh 0 30 15 10 0 10 0 10 15 10 0 30 * gates ijklmn 0 30 20 10 5 10 5 10 20 10 0 30 gates ijklmn 0 30 15 10 0 10 0 10 15 10 0 30 if station A pc_mode ap_by_ap pc_phases abcdefghijklmn 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * above superfluous but left in for clarity if station K pc_mode manual pc_phases abcdefgh 332 156 324 276 255 27 275 16 * for X band pc_phases ijklmn 255 269 315 190 231 142 * for S band if station D pc_mode ap_by_ap pc_phases abcegh 0 -11 -20 3 6 -10 pc_phases ijklmn 0 -1 -4 -5 2 -1 if station L pc_mode ap_by_ap pc_phases abcegh 0 14 7 3 11 1 pc_phases ijklmn 0 -25 -22 1 10 -13 if station V * pc_mode manual pc_mode ap_by_ap pc_phases abcdefgh 0 -11 -14 -5 -6 -8 -8 -6 pc_phases ijklmn 0 5 5 7 -11 14 if station T * pc_mode manual pc_mode ap_by_ap pc_phases abcdefgh 0 -6 -6 10 -7 1 -2 -4 pc_phases ijklmn 0 7 -7 29 -1 -9